เครื่องวัดความขุ่นน้ำ Turbidity Meter, HANNA HI83749-02

เครื่องวัดค่าความขุ่นของน้ำ (Turbidity Meter) สามารถวัดหาค่าความขุ่นใสของน้ำ, เครื่องดื่ม หรืออาหาร

The HI83749 measures turbidity of samples from 0.00 to 1200 NTU (Nephelometric Turbidity Units) and is USEPA compliant. สำหรับงานภาคสนาม สำหรับห้อง LAB ห้องทดลอง เพื่อวัดค่าคุณภาพของน้ำ

HI83749-02 : Portable Turbidity and Bentonite Check Meter ยี่ห้อ HANNA, Romania

Turbidity Meter เครื่องวัดความขุ่นของน้ำ HI83749-02

The HI83749 Portable Turbidity and Bentocheck Meter is specially designed for measurement of turbidity in wine. The instrument is based on a state-of-the-art optical system which guarantees accurate results, assures long term stability, and minimizes stray light and color interferences. It also compensates for variations in intensity of the lamp, although proper calibration ensures measurements are fully validated, comparable, and in compliance with regulatory requirements. The 25 mm round cuvettes composed of special optical glass guarantee the repeatability of turbidity measurements.
Features at-a-glance

AMCO AEPA-1 Primary Turbidity Standard - The AMCO AEPA-1 supplied standards are recognized as a primary standard by the USEPA. These non-toxic standards are made of styrene divinylbenzene polymer spheres that are uniform in size and density. The standards are reusable and stable with a long shelf life.

Calibration A two, three, or four-point turbidity calibration can be performed by using the supplied (<0.1, 10, 100, and 500 NTU) standards. Calibration points can be modified if user-prepared standards are used.

Fast Tracker - For users taking measurements throughout the winemaking process, the HI83749 is equipped with Fast Tracker - Tag Identi˜fication System (T.I.S.) that makes data collecting and management simpler than ever. Fast Tracker allows winemakers to record the time and location of a speci˜fic measurement or series of measurements using iButton tags on specific tanks for quick and easy readings. Each iButton® tag contains a computer chip with a unique identi˜cation code encased in stainless steel.

GLP DataThe HI83749 features complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. Data includes calibration points, date, and time.

Data Logging Up to 200 measurements can be stored in the internal memory and recalled at any time.

Data Transfer For further storage or analysis options, logged data can be downloaded to a Windows compatible PC using the RS232 or USB port and the HI92000 software.

Backlit Display – A backlit LCD display provides an easy to understand, user-friendly interface. Displayed codes guide the user step-by-step through routine operation and calibration.

Specifications:
Range  0.00 to 9.99; 10.0 to 99.9; 100 to 1200 NTU
Resolution  0.01; 0.1; 1 NTU
Range Selection  automatic
Accuracy  ±2% of reading plus 0.05 NTU
Repeatability  ±1% of reading or 0.02 NTU, whichever is greater
Stray Light  < 0.05 NTU
Light Detector  silicon photocell
Method  ratio nephelometric method
Measuring Mode  normal, average, continuous
Turbidity Standards  < 0.1, 10, 100, and 500 NTU
Calibration  two, three, or four-point calibration

General Specifications:
Light Source  tungsten filament lamp / greater than 100,000 readings
Display  60 x 90 mm backlit LCD
Log Memory  200 records
Connectivity  USB or RS232
Environment  0 to 50°C (32 to 122°F), RH max 95% non-condensing
Power Supply  1.5V AA alkaline batteries (4) or AC adapter; auto-off after 15 minutes of non-use
Dimensions  224 x 87 x 77 mm (8.8 x 3.4 x 3.0”)
Weight  512 g (18 oz.)
Ordering Information  - HI83749 is supplied with sample cuvettes and caps (6), 4 calibration cuvettes (HI83749-11),
 - Bentocheck reagent (HI83749-20), silicone oil (HI93703-58),
 - 1000 μL automatic pipette with two tips and instructions sheet,
 - 25 mL glass vials with caps (4),
 - 1 mL syringe with two tips, funnel, filter paper (25),
 - Cuvette cleaning cloth,
 - AC adapter, batteries,
 - Five tag holders with tags (HI 920005),
 - Instruction manual, instrument quality certificate, and rugged carrying case.


Order Information:

  • HI83749 is supplied with sample cuvettes and caps (6), 4 calibration cuvettes (HI83749-11),
  • Bentocheck reagent (HI83749-20), silicone oil (HI93703-58),
  • 1000 μL automatic pipette with two tips and instructions sheet,
  • 25 mL glass vials with caps (4),
  • 1 mL syringe with two tips, funnel, filter paper (25),
  • Cuvette cleaning cloth,
  • AC adapter, batteries,
  • Five tag holders with tags (HI 920005),
  • Instruction manual, instrument quality certificate, and rugged carrying case.

CE  waranty12 เครื่องวัดความขุ่น Turbidity Meter HANNA HI83749-02

หมายเหตุ ::
• ราคาสินค้ารวม ยังไม่รวมภาษีมูลค่าเพิ่ม 7%
• ราคาสินค้าไม่รวมค่าขนส่ง
• สเปคและราคาสินค้าอาจมีการเปลี่ยนแปลงโดยไม่แจ้งให้ทราบล่วงหน้า

measuring instruments  Download Brochure ดาวโหลดโบร์ชัวร์สินค้า
Download   HI83749 Brochure (0kb)

 

ค่าความขุ่นของแหล่งน้ำ: แหล่งน้ำโดยทั่วไปไม่ควรมีค่าความขุ่นเกินกว่า 100 NTU เพราะจะส่งผลกระทบต่อการดำรงชีวิตของสัตว์และพืชน้ำ นอกจากนี้ จะมีผลต่อระบบการผลิตน้ำประปาที่ต้องเพิ่มค่าใช้จ่ายสำหรับสารเคมีในการ กำจัดตะกอนของน้ำ

  • น้ำใสจะมีค่าความขุ่นไม่เกิน 25 NTU
  • น้ำขุ่นปานกลางมีค่าความขุ่นระหว่าง 25 – 100 NTU
  • น้ำขุ่นมากจะมีค่าความขุ่นเกิน 100 NTU
  • ส่วนค่ามาตรฐานความขุ่นของน้ำประปา จะมีค่าไม่เกิน 5 NTU

อ้างอิงจากค่ามาตรฐานของการประปาส่วนภูมิภาค
ที่มา : www.pcd.go.th/contact/FAQs_water.html