เครื่องวัดความขุ่นน้ำ Turbidity Meter, HANNA HI93703C

เครื่องวัดค่าความขุ่นของน้ำ (Turbidity Meter) สามารถวัดหาค่าความขุ่นใสของน้ำ, เครื่องดื่ม หรืออาหาร

Turbidity Meter with Fast Tracker™ Technology, EPA Compliant สำหรับงานภาคสนาม สำหรับห้อง LAB ห้องทดลอง เพื่อวัดค่าคุณภาพของน้ำ

HI93703C : Turbidity Benchtop Meter ยี่ห้อ HANNA

Turbidity Meter เครื่องวัดความขุ่นของน้ำ HI93703C ครบชุดพร้อมกล่อง

The HI93703 Portable Turbidity Meter is specially designed for water quality measurements, providing reliable and accurate readings, even within low turbidity ranges. The instrument is based on a state-of-the-art optical system which guarantees accurate results, assures long term stability, and minimizes stray light and color interferences. Periodic calibration with the supplied standards compensates for any variations in intensity of the LED light source. The 25 mm round cuvettes composed of special optical glass guarantee the repeatability of turbidity measurements.
Features at-a-glance

Single Beam Design - The HI93703 measures turbidity using a light detector at 90° for detection of scattered light. Turbidity measurements can be made in the 0.00 to 1000 FTU range.

ISO Compliant -  The HI93703 meets and exceeds the requirements of ISO 7027 method for turbidity measurements by use of an infrared LED light source. As this meter has been designed to follow this ISO method, the units are displayed in FTU (Formazine Turbidity Unit); FTU is equivalent to the other internationally recognized unit of NTU (Nephelometric Turbidity Unit).

Calibration – The HI93703 has a powerful calibration function that compensates for variation in light intensity. The calibration can be done using the supplied calibration solutions or user-prepared standards. A two or three-point turbidity calibration can be performed by using the supplied (0, 10, and 500 FTU) standards.

AMCO AEPA-1 Primary Turbidity Standard - The AMCO AEPA-1 supplied standards are recognized as a primary standard by the USEPA. These non-toxic standards are made of styrene divinylbenzene polymer spheres that are uniform in size and density. The standards are reusable and stable with a long shelf life.

Last Calibration Date – The HI93703 allows the user to store the last calibration date. Recall of the last calibration date is simple with a press of the “DATE” button on the face of the meter.

Low Battery Indicator – A "LO BAT" indication will appear on the lower right corner of the display when the batteries are low and need to be replaced. At this point, the instrument can still perform approximately 50 measurements. When the battery is too low to perform reliable measurements, a message appears and the meter will automatically switch off.

Specifications:
 Range  0.00 to 1000 FTU
 Resolution  0.01 (0.00 to 50.00 FTU); 1 (50 to 1000 FTU)
 Accuracy  ±0.5 FTU or ±5% of reading (whichever is greater)
 Calibration  three points (0 FTU, 10 FTU and 500 FTU)
 Light Detector  silicon photocell
 Light Source / Life  infrared LED / life of instrument
 Battery Type / Life  1.5V AA (4) /approximately 60 hours of continuous use or 900 measurements;
 auto-off after 5 minutes of non-use
 Environment  0 to 50°C (32 to 122°F); RH max 95% (non condensing)
 Dimensions  220 x 82 x 66 mm (8.7 x 3.2 x 2.6’’)
 Weight  510 g (1.1 lb.)
 Ordering Information  Each HI93703 (meter only) is supplied complete with: glass cuvette with cap,
 Batteries (4 x 1.5V AA), and instructions.
 Each HI93703C is a complete kit supplied with: 2 glass cuvettes with caps,
 Batteries (4 x 1.5V AA) and instructions,
 HI93703-0 & HI93703-10 cal. solutions, HI93703-50 cleaning solution,
 Tissue for wiping cuvettes, adn a rugged carrying case.

 

Order Information:

  • Each HI93703 (meter only) is supplied complete with: glass cuvette with cap, batteries (4 x 1.5V AA), and instructions.
  • Each HI93703C is a complete kit supplied with: 2 glass cuvettes with caps, batteries (4 x 1.5V AA) and instructions,HI93703-0 & HI93703-10 cal. solutions, HI93703-50 cleaning solution, tissue for wiping cuvettes, adn a rugged carrying case.
 

CE  waranty12 เครื่องวัดความขุ่น Turbidity Meter HANNA HI93703

หมายเหตุ ::
• ราคาสินค้ารวม ยังไม่รวมภาษีมูลค่าเพิ่ม 7%
• ราคาสินค้าไม่รวมค่าขนส่ง
• สเปคและราคาสินค้าอาจมีการเปลี่ยนแปลงโดยไม่แจ้งให้ทราบล่วงหน้า

measuring instruments  Download Brochure ดาวโหลดโบร์ชัวร์สินค้า
 
Download   HI93703 Brochure (0kb)

 

ค่าความขุ่นของแหล่งน้ำ: แหล่งน้ำโดยทั่วไปไม่ควรมีค่าความขุ่นเกินกว่า 100 NTU เพราะจะส่งผลกระทบต่อการดำรงชีวิตของสัตว์และพืชน้ำ นอกจากนี้ จะมีผลต่อระบบการผลิตน้ำประปาที่ต้องเพิ่มค่าใช้จ่ายสำหรับสารเคมีในการ กำจัดตะกอนของน้ำ

  • น้ำใสจะมีค่าความขุ่นไม่เกิน 25 NTU
  • น้ำขุ่นปานกลางมีค่าความขุ่นระหว่าง 25 – 100 NTU
  • น้ำขุ่นมากจะมีค่าความขุ่นเกิน 100 NTU
  • ส่วนค่ามาตรฐานความขุ่นของน้ำประปา จะมีค่าไม่เกิน 5 NTU

อ้างอิงจากค่ามาตรฐานของการประปาส่วนภูมิภาค
ที่มา : www.pcd.go.th/contact/FAQs_water.html