เครื่องวัดออกซิเจนในน้ำ Portable Dissolved Oxygen Meter, Hanna HI 9146-04

เครื่องวัดออกซิเจนที่ละลายในน้ำ > Dissolved Oxygen DO Meter > เครื่องวัดออกซิเจนในน้ำ Dissolved Oxygen Meter > DO Meter

เครื่องวัดค่าปริมาณออกซิเจนที่ละลาย (DO) และ อุณหภูมิ สำหรับออกภาคสนาม Dissolved Oxygen Meter

HI 9146: Portable Dissolved Oxygen Meter ยี่ห้อ Hanna, USA

HI 9146 is a water-resistant, dissolved oxygen meter that measures up to 300% saturation or 45 ppm (mg/L) with temperature compensation and automatic calibration. It has been developed for DO and temperature measurement in water, wastewater, and applications such as fish farming.

This instrument also allows altitude compensation up to 4000 m and the ppm and % saturation are both compensated for changes in solubility of oxygen in water and for permeability of the membrane as well as the temperature effect.

The included polarographic probe features built-in temperature compensation and removable protective membrane cover.

Features:

  • On-screen tutorial messages
  • Two point calibration
  • Auto endpoint
  • DO range up to 300%, temperature compensated
  • Altitude compensation up to 4000 m
  • Salinity compensation up to 80 g/L
  • Automatic calibration in air
  • GLP features
  • Low battery indicator

Specifications:
Range O2 0.00 to 45.00 mg/L
Range % Saturation O2 0.0 to 300.0%
Range Temperature 0.0 to 50.0°C
Resolution O2 0.01 mg/L
Resolution % Saturation O2 0.1%
Resolution Temperature 0.1°C
Accuracy O2 ±1.5% F.S.
Accuracy % Saturation O2 ±1.5% F.S.
Accuracy Temperature 0.5°C
Calibration   automatic, in air, at 100%
Temperature Compensation   automatic, 0 to 50°C (32 to 122°F)
Altitude Compensation   0 to 1900 m (100 m 326' resolution)
Salinity Compensation   0 to 40 g/L (1g/L resolution)
Probe   HI 76407/4F with 4 m cable
Power Supply   4 x 1.5 AA batteries / approx. 200 hours of continuous use;
auto-off after 4 hours of inactivity; or input for 12 Vdc power adapter
Environment   0 to 50°C (32 to 122°F); RH max 100%
Dimensions   196 x 80 x 60 mm (7.7 x 3.1 x 2.4")
Weight   500 g (1.1 lb.)
Range O2 0.00 to 45.00 mg/L
Range % Saturation O2 0.0 to 300.0%
Range Temperature 0.0 to 50.0°C
Resolution O2 0.01 mg/L
Resolution % Saturation O2 0.1%
Resolution Temperature 0.1°C
Accuracy O2 ±1.5% F.S.
Accuracy % Saturation O2 ±1.5% F.S.
Accuracy Temperature ±0.5°C
Calibration   automatic, in air, at 100%
Temperature Compensation   automatic, 0 to 50°C (32 to 122°F)
Probe   HI 76407/4F with 4 m cable
Power Supply   4 x 1.5 AA batteries / approx. 200 hours of continuous use;
auto-off after 4 hours of inactivity; or input for 12 Vdc power adapter
Environment   0 to 50°C (32 to 122°F); RH max 100%
Dimensions   196 x 80 x 60 mm (7.7 x 3.1 x 2.4")
Weight   500 g (1.1 lb.)
 
Order Information:
HI 9146-04 is supplied complete with HI 76407/4F probe with 4 m (13.1-) cable, HI 76407A membranes (2), HI 7041S electrolyte solution (30 mL), batteries, instructions and rugged carrying case.
HI 9146-10 is supplied complete with HI 76407/10F probe with 10 m (32.8-) cable, HI 76407A membranes (2), HI 7041S electrolyte solution (30 mL), batteries, instructions and rugged carrying case.
 
CE  UL RoHS 
 
Accessories อุปกรณ์เสริม :
 
Electrodes:
HI 76407/4F - DO Probe with Protective Sleeve, 4 m cable
HI 76407/10F - DO Probe with Protective Sleeve, 10 m cable
 
Solutions:
HI 7040L - Zero Oxygen Solution
HI 7041M - Refilling Electrolyte Solution, 230 mL
HI 7041L - Refilling Electrolyte Solution, 500 mL
HI 7041S - Refilling Electrolyte Solution, 30 mL
 
Accessories:
HI 76407A/P - Membranes for DO Probes
 
หมายเหตุ ::
• ราคาสินค้ารวม ยังไม่รวมภาษีมูลค่าเพิ่ม 7%
• ราคาสินค้าไม่รวมค่าขนส่ง
• สเปคและราคาสินค้าอาจมีการเปลี่ยนแปลงโดยไม่แจ้งให้ทราบล่วงหน้า

measuring instruments

Download ดาวน์โหลดไฟล์ข้อมูลสินค้า

PDF  HI 9146 Brochure (0 KB)
PDF  HI 9146 Instruction Manual (0 KB)

 สั่งซื้อสินค้าออนไลน์ Online Store :

Visitors: 98,150