เครื่องวัดความขุ่นน้ำ Turbidity Meter with Fast Tracker™ Technology, EPA Compliant HANNA HI98703-02

เครื่องวัดค่าความขุ่นของน้ำ (Turbidity Meter) สามารถวัดหาค่าความขุ่นใสของน้ำ, เครื่องดื่ม หรืออาหาร

Turbidity Meter with Fast Tracker™ Technology, EPA Compliant สำหรับงานภาคสนาม สำหรับห้อง LAB ห้องทดลอง เพื่อวัดค่าคุณภาพของน้ำ

HI 98703: Turbidity Benchtop Meter ยี่ห้อ HANNA

  • High accuracy at low ranges (below 0.05 NTU)
  • Two, three or four point calibration
  • USB and RS232 PC connectivity
  • Log up to 200 records
  • GLP Features
  • User friendly, backlit  display with guidance codes
  • Battery % on startup
  • Continuous current time on display
 

The HI 98703 meets and exceeds the requirements of the USEPA Method 180.1 for wastewater and Standard Method 2130 B for drinking water. The instrument has an EPA compliance reading mode which rounds readings to meet EPA reporting requirements. Users will appreciate the accuracy and sensitivity of this instrument, particularly at very low turbidity levels.

This instrument incorporates complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. The last calibration points,
time and date can be checked at the touch of a button.

With it’s logging function, up to 200 measurements along with it’s tagged locations can be stored in internal memory and consulted at any time. Data can be later transferred to a PC via RS232 or USB interface and HANNA HI 92000 software (optional).

Exclusive Fast Tracker™

For advanced field applications, the HI 98703 is equipped with Fast Tracker™—Tag Identification System (T.I.S.) that makes data collecting and management simpler than ever. Fast Tracker™ allows users to record the time and location of a specific measurement or series of measurements.

Specifications:
Range  0.00 to 9.99; 10.0 to 99.9 and 100 to 1000 NTU
Range Selection  automatic
Resolution  0.01 NTU from 0.00 to 9.99 NTU; 0.1 NTU from 10.0 to 99.9 NTU; 1 NTU from 100 to 1000 NTU
Accuracy @25°C  ±2% of reading plus 0.02 NTU
Repeatability  ±1% of reading or 0.02 NTU, whichever is greater
Stray Light  < 0.02 NTU
Light Detector  silicon photocell
Light Source  tungsten filament lamp
Lamp Life  greater than 100,000 readings
Method  Ratio Nephelometric Method (90°), ratio of scattered and transmitted light; Adaptation of the USEPA Method 180.1 and Standard Method 2130 B
Measuring Mode  normal, average, continuous
Turbidity Standards  <0.1, 15, 100 and 750 NTU
Calibration  two, three or four-point calibration
Log Memory  200 records
PC Connectivity  USB or RS232
Environment  up to 50°C (122°F); RH max 95% non-condensing
Power Supply  1.5V AA alkaline batteries (4) or AC adapter; auto-off after 15 minutes of non-use
Dimensions / Weight  224 x 87 x 77 mm (8.8 x 3.4 x 3.0”) / 512 g (18 oz.)

 

Order Information:
HI 98703-01 (115V), HI 98703-02 (230V) and HI 98703-03 (AUS plug) are supplied with sample cuvettes and caps (5), HI 98703-11 calibration cuvettes, HI 93703-58 silicone oil, cuvette cleaning cloth, batteries, AC adapter, instruction manual and rugged carrying case.

Solutions
Cuvette Cleaning Solution
Reagents & Standards
HI 98703-11 Turbidity Calibration Standards
 

CE  waranty12 เครื่องวัดค่าความขุ่นของน้ำ (Turbidity Meter) เครื่องวัดความขุ่นใสของน้ำ

หมายเหตุ ::
• ราคาสินค้ารวม ยังไม่รวมภาษีมูลค่าเพิ่ม 7%
• ราคาสินค้าไม่รวมค่าขนส่ง
• สเปคและราคาสินค้าอาจมีการเปลี่ยนแปลงโดยไม่แจ้งให้ทราบล่วงหน้า

measuring instruments Download Brochure ดาวโหลดโบร์ชัวร์สินค้า
Download  HI 98703 Brochure (0kb)

 

ค่าความขุ่นของแหล่งน้ำ: แหล่งน้ำโดยทั่วไปไม่ควรมีค่าความขุ่นเกินกว่า 100 NTU เพราะจะส่งผลกระทบต่อการดำรงชีวิตของสัตว์และพืชน้ำ นอกจากนี้ จะมีผลต่อระบบการผลิตน้ำประปาที่ต้องเพิ่มค่าใช้จ่ายสำหรับสารเคมีในการ กำจัดตะกอนของน้ำ

  • น้ำใสจะมีค่าความขุ่นไม่เกิน 25 NTU
  • น้ำขุ่นปานกลางมีค่าความขุ่นระหว่าง 25 – 100 NTU
  • น้ำขุ่นมากจะมีค่าความขุ่นเกิน 100 NTU
  • ส่วนค่ามาตรฐานความขุ่นของน้ำประปา จะมีค่าไม่เกิน 5 NTU

อ้างอิงจากค่ามาตรฐานของการประปาส่วนภูมิภาค